| RUio0804-D | ||
|---|---|---|
| I/O Connectors | Analog Input | 8 |
| Analog Output | 4 | |
| Sampling frequency rate | External | 44.1 kHz / 48 kHz / 88.2 kHz / 96 kHz ±200 ppm +4.1667%, +0.1%, −0.1%, −4.0% ±200 ppm |
| Signal delay | Less than 1.7 ms@Fs=96 kHz, 2.0 ms@Fs=48 kHz. RUio0804-D INPUT to RUio0804-D OUTPUT connect with DM5 using Dante. Dante Receive Latency set to 0.25 ms | |
| Total harmonic distortion | Less than 0.05% +4 dBu@20 Hz - 20 kHz, GAIN : 0 dB into 10k Ω, Less than 0.15% +4 dBu@20 Hz - 20 kHz, GAIN: +64 dB into 10k Ω | |
| Frequency response | +0.5, –1.5 dB 20 Hz - 20 kHz, refer to +4 dBu output @1 kHz, input to output, Fs= 48 kHz or 96 kHz | |
| Dynamic range | 114 dB typ., DA Converter, 109 dB typ., Input to Output, GAIN: 0 dB | |
| Hum & noise level | Equivalent input noise | -128 dBu typ., GAIN: +64 dB |
| Residual output noise | -88 dBu, main stereo channel off | |
| Crosstalk | INPUT: -100 dB, adjacent inputs, GAIN: 0 dB, @1 kHz, OUTPUT: -100 dB, input to output, @1 kHz | |
| Power requirements | 100–240 V, 50 Hz/60 Hz | |
| Power consumption | 30 W | |
| Dimensions | W | 480 mm (18.9”) |
| H | 44 mm (1.7”) | |
| D | 369 mm (14.5”) | |
| Net weight | 3.7 kg (8.2lb) | |
| Accessories | Read This First × 1, AC Power cord × 1 | |
| Others | NC Value: Fan Speed LOW: NC=20 / HIGH: NC=25 (Measurement position: 1 m from the front of the unit), Operating temperature range: 0 to 40°C, Storage temperature range: -20 to 60°C | |
- Total harmonic distortion is measured using an 80 kHz, 48 dB/octave low pass filter.
- Hum & noise levels are measured using an A-weight filter.
- Crosstalk is measured using a 22 kHz, 48 dB/octave filter.
Analog Input Standards *3*4
*1 Sensitivity is the minimum level needed to output +4 dBu (1.23 V) or the specified level when the gain is set to maximum. (All faders and level controls are set to maximum.)
*2 1=GND, 2=HOT, 3=COLD
*3 0 dBu = 0.775 Vrms.
*4 +48V DC (phantom power) is supplied to INPUT XLR type connectors via each individual software-controlled switch.
Analog Output Standards *2
*1 1=GND, 2=HOT, 3=COLD
*2 0 dBu = 0.775 Vrms.
*3 You can change the output level for the OUTPUT 1–16 {1–4} connectors. Contact your Yamaha dealer.
Digital I/O Standards
*1 CAT5e or higher cables are recommended for connections.
Control I/O Standards